  • Monitoring of direct or alternating voltages in live systems
  • It is displayed whether the adjusted values are exceeded or not reached, and a switching process is triggered
  • The integrated 7-segment display indicates the sources of the fault
Cena: dostupná po přihlášení
Dostupnost: Brno
 
Praha
 
na vyžádání
Množství:  ks
  • Monitoring of direct or alternating voltages in live systems
  • It is displayed whether the adjusted values are exceeded or not reached, and a switching process is triggered
  • The integrated 7-segment display indicates the sources of the fault
  • The voltage to be measured (AC or DC), two measuring ranges, an upper and a lower threshold value, a response delay and the fault memory (ON or OFF) can be adjusted manually on the device
  • Faults can be acknowledged directly on the device or by means of an external contact

Technická specifikace

Operating voltage 230 V AC, 50 Hz
Current consumption max. 15 mA
Voltage measuring input B1 - B3 10 V to 300 V
Voltage measuring input B2 - B3 1 V to 100 V
Response delay 0.1 to 9.9 s, adjustable
Output / contact 2 changeover contacts (DPDT)
Output / switching voltage max. 250 V AC/DC
Output / continuous current max. 8 A
Mechanical endurance 3 x 107 switching cycles
Electrical endurance 1 x 105 switching cycles
Display / error Two 7-segment displays
Display Green and red LED
   
Dimensions (W x H x D) 50 x 69.3 x 60 mm
Weight 200 g
Operating temperature range -5 °C to +55 °C
Storage temperature range -20 °C to +70 °C
Ingress protection for housing / terminal block IP40 / IP20

Originální text

Monitoring of direct or alternating voltages in live systems. It is displayed whether the adjusted values are exceeded or not reached, and a switching process is triggered. The integrated 7-segment display indicates the sources of the fault. The voltage to be measured (AC or DC), two measuring ranges, an upper and a lower threshold value, a response delay and the fault memory (ON or OFF) can be adjusted manually on the device. Faults can be acknowledged directly on the device or by means of an external contact.

Sledujte nás
Navštivte nás

Provozovna BRNO
Na návsi 19

620 00 Brno – Holásky
+420 545 232 258


Provozovna PRAHA
V Korytech 972/12

100 00 Praha
+420 274 770 409

 

Otevírací doba

Po-Pá   08:00 — 16:30

So-Ne   Zavřeno

 

©2017-2024 Vytvořila reklamní agentura kangaroo.cz

Informace o cookies na této stránce

Abyste na našem webu našli vždy to, co potřebujete, využíváme soubory cookies, které zpracováváme podle zásad ochrany osobních údajů. Pro personalizovaný zážitek udělte prosím souhlas se zpracováním všech typů cookies.

 

Nastavení cookies

Cookie soubory, které jsou použité na těchto stránkách jsou rozděleny do kategorií a níže si můžete zjistit o každé kategorii více a povolit nebo zamítnout některé nebo všechny z nich. Jakmile zakážete kategorie, které byly předtím povoleny, budou z vašeho prohlížeče odstraněny všechny soubory cookie přiřazené do této kategorie.