Metz, DRIW-E16, 230 V AC

Metz, DRIW-E16, 230 V ACMetz, DRIW-E16, 230 V ACMetz, DRIW-E16, 230 V ACMetz, DRIW-E16, 230 V AC
Kód: 1101500522
  • The speed and V-belt monitor is used for monitoring the rotary movement (insufficient speed) of motor and V-belt driven shafts
  • Inductive proximity switches are used for capturing the speed
  • Pulses are generated by the sensor without contact by means of driven control cams, toothed wheels, segmented discs, metal signal flags or similar
Cena: dostupná po přihlášení
Dostupnost: Brno
 
Praha
 
na vyžádání
Množství:  ks
  • The speed and V-belt monitor is used for monitoring the rotary movement (insufficient speed) of motor and V-belt driven shafts
  • Inductive proximity switches are used for capturing the speed
  • Pulses are generated by the sensor without contact by means of driven control cams, toothed wheels, segmented discs, metal signal flags or similar
  • The relay is activated when the operating voltage is applied
  • After start-up bridging has finished, the monitoring function is started on the E1 and E2 terminals by means of the power contactor of the drive
  • When the drive speed falls below the switch-off speed, the relay is deactivated
  • The fault message of the speed or V-belt monitor is reset by means of the reset function and by switching off the operating voltage

Technická specifikace

Operating voltage 230 V AC
Recovery time 400 ms
Type of monitoring Low speed
Max. monitoring range 4200 pulses/min
Switch-off range 120 pulses/min
Sensor input Two-wire
Start-up bridging 60 s
Outputs 2 changeover contacts (DPDT)
Output / switching voltage 250 V
Output / current 6 A
Output / total current 8 A / across all contacts
Display Green and red LED
   
Dimensions (W x H x D) 22.5 x 61.3 x 60 mm
Weight 70 g
Operating temperature range 0 °C to +55 °C
Storage temperature range -20 °C to +70 °C
Ingress protection for housing / terminal block IP40 / IP20

Originální text

The speed and V-belt monitor is used for monitoring the rotary movement (insufficient speed) of motor and V-belt driven shafts. Inductive proximity switches are used for capturing the speed. Pulses are generated by the sensor without contact by means of driven control cams, toothed wheels, segmented discs, metal signal flags or similar. The relay is activated when the operating voltage is applied. After start-up bridging has finished, the monitoring function is started on the E1 and E2 terminals by means of the power contactor of the drive. When the drive speed falls below the switch-off speed, the relay is deactivated. The fault message of the speed or V-belt monitor is reset by means of the reset function and by switching off the operating voltage.

Sledujte nás
Navštivte nás

Provozovna BRNO
Na návsi 19

620 00 Brno – Holásky
+420 545 232 258


Provozovna PRAHA
V Korytech 972/12

100 00 Praha
+420 274 770 409

 

Otevírací doba

Po-Pá   08:00 — 16:30

So-Ne   Zavřeno

 

©2017-2024 Vytvořila reklamní agentura kangaroo.cz

Informace o cookies na této stránce

Abyste na našem webu našli vždy to, co potřebujete, využíváme soubory cookies, které zpracováváme podle zásad ochrany osobních údajů. Pro personalizovaný zážitek udělte prosím souhlas se zpracováním všech typů cookies.

 

Nastavení cookies

Cookie soubory, které jsou použité na těchto stránkách jsou rozděleny do kategorií a níže si můžete zjistit o každé kategorii více a povolit nebo zamítnout některé nebo všechny z nich. Jakmile zakážete kategorie, které byly předtím povoleny, budou z vašeho prohlížeče odstraněny všechny soubory cookie přiřazené do této kategorie.